Technical data · Nominal geometry

HEA 220 — dimensions, linear mass and inertia

HEA 220 (HEA sections): h 210 × b 220 × tw 7 × tf 11 mm, mass 48.32 kg/m, A 61.56 cm², Ix 5,184.2 cm⁴ and Iy 1,952.7 cm⁴, recalculated from nominal geometry.

EN 10365
02

Profile geometry

HEA

HEA 220

Compare light HEA sections and open each page for its diagram and recalculated properties.

x x y G 210 h 220 b tf = 11tw = 7

G : centroid x-x and y-y: centroidal axes

Use this profileCopy its data or open a calculation directly.

Cross-check completed

Catalogue and analytical model

The catalogue reference is the value published by the cited sources. The Formulaxis result is a reproducible calculation from simplified nominal geometry; it can differ because real sections include root fillets and other geometric details, and because published values reflect the sources’ rounding and conventions. This comparison is not a regulatory verification.

Cross-check completed
Major axis:y-y → x-x (Ix, Wx)Minor axis:z-z → y-y (Iy, Wy)
Comparison of published and recalculated properties
PropertyCross-checked catalogue valueFormulaxis analytical calculationAnalytical / catalogue differenceUnit
Linear mass50.548.3246-4.31 %kg/m
Section area64.361.56-4.26 %cm²
Second moment of area — major axis5,4095,184.21-4.16 %cm⁴
Second moment of area — minor axis1,9541,952.67-0.07 %cm⁴
Elastic section modulus — major axis515.2493.734-4.17 %cm³
Elastic section modulus — minor axis177.6177.516-0.05 %cm³

Difference = (Formulaxis − catalogue) / catalogue. A positive value means the Formulaxis analytical result is higher; a negative value means it is lower.

Verification status: Cross-check completedChecked on: 2026-08-18

Verified profile

Use this profile in a beam check

Choose the axis, then open a deflection or bending-stress check with the verified catalog value.

Choose the axis

The verified catalog value will be used.You can change the property definition in the calculator.

Selected series

HEA

Select a row to update the diagram and recalculated properties.

DesignationA recalculatedLinear mass recalculatedIx recalculatedIy recalculatedWx recalculatedWy recalculated
HEA 10020 cm²15.7 kg/m331.95 cm⁴133.42 cm⁴69.156 cm³26.683 cm³
HEA 12024.1 cm²18.918 kg/m579.57 cm⁴230.5 cm⁴101.68 cm³38.417 cm³
HEA 14030.18 cm²23.691 kg/m995.24 cm⁴388.89 cm⁴149.66 cm³55.556 cm³
HEA 16036.84 cm²28.919 kg/m1,594.6 cm⁴614.64 cm⁴209.81 cm³76.83 cm³
HEA 18043.32 cm²34.006 kg/m2,408.2 cm⁴923.67 cm⁴281.66 cm³102.63 cm³
HEA 20051.05 cm²40.074 kg/m3,509.5 cm⁴1,333.7 cm⁴369.42 cm³133.37 cm³
HEA 22061.56 cm²48.325 kg/m5,184.2 cm⁴1,952.7 cm⁴493.73 cm³177.52 cm³
HEA 24073.05 cm²57.344 kg/m7,396.7 cm⁴2,765.5 cm⁴643.19 cm³230.46 cm³