Choose pipe diameter without guessing coefficients
A 12 m³/h example: why 40 and 50 mm inside diameters have very different losses.
Here we want to convey 12 m³/h of water at 20 °C over 60 m through new commercial pipe. The teaching aim is to compare three actual inside diameters, not three nominal DN sizes. The calculation describes turbulent flow in straight pipe; it does not by itself size a complete system.
1. Find data instead of guessing
| Input | Value used | Justification and pitfall |
|---|---|---|
| Flow rate Q | 12 m³/h | Exercise process requirement; pump power alone cannot determine it. |
| Inside D | 40, 50, 63 mm | Scenario dimensions that are internal , not standardized DN sizes. Check actual wall thickness/schedule. |
| Water at 20 °C | ρ = 998.16 kg/m³; μ = 1.0016 mPa·s | Density: Hydraulic Institute; reference viscosity: ISO/TR 3666. |
| New commercial steel | ε = 0.045 mm | Bentley roughness example; aging/deposits not represented. |
| Straight length | 60 m | Measured along the route; excludes bends and valves. |
Water and roughness data are retained in the fluid and pipe properties table, with links to the original sources.
2. The five calculation steps
1 Convert flow and calculate velocity
12 m³/h = 0.003333 m³/s. For D = 40 mm, internal area is πD²/4 and velocity approximately 2.65 m/s. Do not use outside diameter or a DN label alone to calculate area: wall thickness actually changes velocity.
2 Determine the regime using Reynolds number
Viscosity depends on temperature and fluid type. For this water example: Re = ρvD/μ ≈ 105 739 at 40 mm diameter. Flow is turbulent, allowing the explicit relationship selected below. Recalculate for another fluid, temperature or transitional regime.
3 Choose roughness with its source
A value of 0.045 mm can serve as anassumption for new commercial steel. It does not automatically apply to drawn stainless steel, polymer or old scaled pipe. ε/D is needed for turbulent calculations. A material data sheet without internal surface condition is insufficient for a detailed study.
4 Calculate straight-pipe losses
We use the explicit Swamee–Jain formula to approximate the turbulent Darcy factor, then Darcy–Weisbach. This is the Darcy factor, not the Fanning factor (a factor of 4 difference). Both diameters are thus compared using the same model and fluid properties.
5 Add local losses and static head
A real network includes bends, valves, strainers, check valves, section changes and sometimes elevation head. Each item needs a documented K, not a generic count of bends. Add head losses and static head to construct the system curve for comparison with the pump curve; fitting K values vary with product and Reynolds number.
3. Numerical example: 40 or 50 mm inside diameter?
At 12 m³/h over 60 m, with identical water and roughness, increasing from 40 to 50 mm reduces straight-pipe loss by about 119.3 → 38.6 kPa. This is not a general rule for changing DN: it follows from the internal diameters in our scenario.
| Inside D | v (m/s) | Re | Darcy f | Straight-pipe Δp (kPa) | H (m) |
|---|---|---|---|---|---|
| 40 mm | 2.65 | 105 739 | 0.02266 | 119.3 | 12.19 |
| 50 mm | 1.70 | 84 591 | 0.02237 | 38.6 | 3.95 |
| 63 mm | 1.07 | 67 136 | 0.02236 | 12.2 | 1.24 |
Try another diameter and flow rate
Water at 20 °C, ε = 0.045 mm (new commercial steel), same turbulent model; automatic rejection outside the Swamee–Jain range.
4. Common pipe-calculation errors
DN 50 does not mean inside D = 50 mm
DN is a nominal designation, not necessarily actual diameter. For a pipe, determine outside diameter and wall thickness (or schedule), then calculate the flow diameter. The difference enters the area quadratically and strongly affects losses.
Using “standard” roughness for an old line
Scale, corrosion or welds can change the internal condition. For a pipe in service for years, comparing several plausible roughness values is more useful than quoting 0.045 mm to six decimal places.
Ignoring fittings can hide the real problem
A partly closed valve or clogged filter can dominate losses even if the straight pipe is correctly sized. Check equipment positions and manufacturer curves or K values, especially in compact networks with many fittings.
5. Workflow through existing calculators
Related tables: water and roughness with Bentley / Hydraulic Institute / ISO sources. Calculating local losses requires the actual fitting type, not a fictitious “standard” ΣK value.
Sources and data status
Numerical values are retained in this document even if URLs change. The tables are reconstructed selections with source attribution, not full copies of brochures. Formulaxis calculations and teaching assumptions are identified separately.
- Hydraulic Institute — water propertiesWater density at 20 and 40 °C.
- ISO/TR 3666 — water viscosity (reference)Dynamic viscosity of water at 20 °C; explanatory extract consulted.
- Bentley OpenFlows — Darcy–Weisbach roughnessApproximate roughness values for new pipes; no universal value.
- ASHRAE — Pipe Design / local lossesFitting K values vary with geometry and flow regime.
Sources consulted / results cross-checked on 15 November 2026. Data sheets and catalogues may be revised: check the current edition for a real project.