Skip to content
Formulaxis
Sourced data · selected extract

Water and pipe roughness: calculation references

Water density and viscosity at 20/40 °C, indicative roughness for new pipe materials and conditions of use.

Formulaxis · Documented technical demonstration · Revision: 15 November 2026

What is this table for? Water density and viscosity at 20/40 °C, indicative roughness for new pipe materials and conditions of use.

Fluid properties ≠ internal pipe condition

Dynamic viscosity μ and density ρ must be taken at the same temperature. Roughness ε is a wall parameter that differs for new, corroded or fouled pipes. Using it with inside diameter D is essential for the Colebrook / Swamee–Jain relationship.

The table combines rows from different sources without claiming roughness depends on water or remains unchanged throughout pipe life.

Initial data: water and walls

Fluid or surfaceDensity ρViscosity μ / roughness εSource
Water at 20 °C998.16 kg/m³1.0016 mPa·sHydraulic Institute + ISO/TR 3666
Water at 40 °C992.18 kg/m³≈ 0.6524 mPa·sρ: HI; μ: ISO ratio × μ20
New commercial steel—ε = 0.045 mmBentley OpenFlows
Galvanized steel—ε = 0.15 mmBentley OpenFlows
New drawn copper—ε = 0.0015 mmBentley OpenFlows

Here μ at 40 °C is calculated from the ISO ratio 0.6514 × 1.0016 mPa·s; it is not a new value directly measured by Formulaxis.

An unambiguous dimension example

For new commercial steel ε = 0.045 mm and an inside diameter D = 50 mm, ε/D = 0.0009 (dimensionless). Do not enter 0.045 m in the SI formula: the error is a factor of 1 000.

An existing line's roughness must be confirmed by actual condition, history, measurements or documented sensitivity assumptions.

Return to the practical example

Values are useful only when assumptions, dimensions, axes and reference conditions are consistent with the calculation. Guide: diameter and pressure losses

Sources and data status

Numerical values are retained in this document even if URLs change. The tables are reconstructed selections with source attribution, not full copies of brochures. Formulaxis calculations and teaching assumptions are identified separately.

  1. Hydraulic Institute — water propertiesWater density at 20 and 40 °C.
  2. ISO/TR 3666 — water viscosity (reference)Dynamic viscosity of water at 20 °C; explanatory extract consulted.
  3. Bentley OpenFlows — Darcy–Weisbach roughnessApproximate roughness values for new pipes; no universal value.

Sources consulted / results cross-checked on 15 November 2026. Data sheets and catalogues may be revised: check the current edition for a real project.