Profile library · Comparison

Rectangular steel tubes: dimensions, mass and inertia

Compare rectangular tubes by width, height, wall thickness and section properties.

8 references

Included families

Compare before opening a data page

The values below are recalculated from simplified nominal geometry. Open a designation to inspect its diagram, dimensions and all available properties.

Rectangular tubes

Comparison table

Rectangular tubes

Select a designation to open its dedicated data page.

DesignationMain dimensionsAMassIxIyWxWy
40 × 20 × 2h=40 mm · b=20 mm · t=2 mm · r=3 mm2.24 cm²1.7584 kg/m4.4459 cm⁴1.4379 cm⁴2.2229 cm³1.4379 cm³
50 × 30 × 2.5h=50 mm · b=30 mm · t=2.5 mm · r=3 mm3.75 cm²2.9438 kg/m12.266 cm⁴5.3906 cm⁴4.9063 cm³3.5938 cm³
60 × 40 × 3h=60 mm · b=40 mm · t=3 mm · r=3 mm5.64 cm²4.4274 kg/m27.385 cm⁴14.313 cm⁴9.1284 cm³7.1566 cm³
80 × 40 × 3h=80 mm · b=40 mm · t=3 mm · r=3 mm6.84 cm²5.3694 kg/m55.853 cm⁴18.429 cm⁴13.963 cm³9.2146 cm³
100 × 50 × 4h=100 mm · b=50 mm · t=4 mm · r=4 mm11.36 cm²8.9176 kg/m144.13 cm⁴47.366 cm⁴28.825 cm³18.946 cm³
120 × 60 × 4h=120 mm · b=60 mm · t=4 mm · r=4 mm13.76 cm²10.802 kg/m255.2 cm⁴84.766 cm⁴42.533 cm³28.255 cm³
150 × 100 × 5h=150 mm · b=100 mm · t=5 mm · r=5 mm24 cm²18.84 kg/m754.5 cm⁴399.5 cm⁴100.6 cm³79.9 cm³
200 × 100 × 6h=200 mm · b=100 mm · t=6 mm · r=6 mm34.56 cm²27.13 kg/m1,793.9 cm⁴599.03 cm⁴179.39 cm³119.81 cm³

Included families

Compare before opening a data page

The values below are recalculated from simplified nominal geometry. Open a designation to inspect its diagram, dimensions and all available properties.

Continue the calculation

Reuse the selected properties

Area is used for linear mass, section modulus for bending, and radius of gyration for buckling.