Strength of materials and structural sizing
Section: calculate mass per unit length and weight
Calculate a section's mass in kg and weight in N from its length. Select a steel catalogue section, enter a material area and a material, or use a known mass per unit length. The results also give mass per metre in and self-weight per metre in .
Calculation inputs
Section mass
Calculation details
m = μcat × L = (22.4 kg/m) × (6 m) = 134.4 kg. Mass for the entered length; this is the quantity needed for an estimate in kilograms.Calculation details
μ = μcat = (22.4 kg/m) = 22.4 kg/m. Mass per unit length, independent of total length and gravitational acceleration.Calculation details
P = μcat × L × g = (22.4 kg/m) × (6 m) × (9.81 m/s²) = 1,318.46 N. Magnitude of the gravitational force over the entered length, directed vertically downward.Calculation details
q = μcat × g = (22.4 kg/m) × (9.81 m/s²) = 219.74 N/m. Distributed load due to the profile’s weight, useful in beam calculations. It is not used to obtain mass in kg.The kg value gives the mass to be transported. Self-weight in N/m is the distributed load to use in a beam calculation; it is not used to calculate mass.
Calculation details
The steps follow the selected method and entered length. Inputs are converted to SI units for the calculation; displayed values are rounded without rounding intermediate calculations.
02 · Calculate mass over the entered length
03 · Convert mass per unit length to weight per unit length
04 · Calculate total weight
Mass, weight and mass per unit length: what is the difference?
In everyday language, a section's “weight” often means its mass in kilograms. In mechanics, weight is a force expressed in newtons. Mass per unit length μ is usually given in ; it converts a section reference into the mass of a cut length. Weight per unit length q, in or , represents the gravitational load distributed along the section.
In Steel catalogue mode, the selected reference directly provides its published mass per unit length. The catalogue includes IPE sections and their variants, HE series, UPN and UPE sections, equal- and unequal-leg angles, and square, rectangular and circular tubes. For tubes, the hot-finished or cold-formed manufacturing process is part of the reference and must match the product used.
In Area and material mode, enter the cross-sectional area of material and its density. This mode also suits a flat bar, round bar, tube or custom extrusion whose area has been calculated or measured. Material selection applies only in this mode; it does not turn a steel catalogue reference into an aluminium section.
In Known mass per unit length mode, use the value on the supplier's datasheet. Section selection and density do not enter this calculation. In every mode, doubling length doubles mass and total weight, while μ and q remain unchanged.
Formulas and symbols
The formulas below correspond to the selected mode. For a homogeneous, constant cross-section, the general relationship is . Mass and weight then follow from and ; weight per unit length is .
The tabulated value is used directly. Multiplying the rounded area by a conventional density may give a slightly different result.
Mass for the entered length; this is the quantity needed for an estimate in kilograms.
Self-weight force per unit of actual length, before any design factors.
Magnitude of the gravitational force over the entered length, directed vertically downward.
- μ: section mass per unit length, in .
- μcat: mass per unit length published in the catalogue, in .
- μs: directly entered mass per unit length, in after conversion.
- ρ: material density, in .
- A: cross-sectional area of material, in .
- L: actual section length, in m.
- g: gravitational acceleration, in .
- m: mass of the entered length, in kg.
- q: self-weight per unit of actual length, in .
- P: magnitude of the total weight, in N.
Choose the starting data
Comparison of the three supported starting inputs: a steel catalogue reference, a material area with its density, or an already known mass per unit length.
| Available data | Mode to select | Point to check |
|---|---|---|
| An IPE, HE, U, angle or tube reference listed in the catalogue | Steel catalogue | Check the series and, for tubes, the manufacturing process. |
| A known cross-sectional area and material | Area and material | Enter the material area and the density of the correct grade. |
| A supplier value in or | Known mass per unit length | Check that it is mass per unit length, not a force or a total mass. |
The tabulated mass of a standard section is used as published. Rounding, fillets and the source's geometric conventions may explain differences from an estimate using rectangles. Sources for the first group: ArcelorMittal for open sections, SCI Blue Book for hot-finished or cold-formed tubes. The other two rows describe this calculator's input modes; they do not give catalogue values. ArcelorMittal Orange Book — masses and properties of IPE profiles and variants ; ArcelorMittal Orange Book — masses and properties of HE profiles ; ArcelorMittal Orange Book — masses and properties of UPE profiles ; ArcelorMittal Orange Book — masses and properties of UPN profiles ; ArcelorMittal Orange Book — equal-leg angles ; ArcelorMittal Orange Book — unequal-leg angles ; SCI / Steel for Life — hot-finished circular hollow sections, EN 10210-2 ; SCI / Steel for Life — hot-finished square hollow sections, EN 10210-2 ; SCI / Steel for Life — hot-finished rectangular hollow sections, EN 10210-2 ; SCI / Steel for Life — cold-formed circular hollow sections, EN 10219-2 ; SCI / Steel for Life — cold-formed square hollow sections, EN 10219-2 ; SCI / Steel for Life — cold-formed rectangular hollow sections, EN 10219-2.
Densities of the five presets
Reference table limited to the five presets in Area and material mode: structural steel, aluminium 6060, aluminium 6063, stainless steel 304 and stainless steel 316L. The values are nominal; the calculation uses them at ambient temperature, close to 20 °C. They do not define a temperature-dependent law. For another grade or condition, enter a sourced value under Custom.
| Material or grade | Density | Reference and use |
|---|---|---|
| Structural steel | 7 850 | Bauforumstahl, EPD-BFS-20230271-IBG1-EN, §2.3: S235 to S500 sections and bars. |
| Aluminium 6060 | 2 700 | Aluminum Association, Teal Sheets December 2025, designation 6060: calculated nominal density. |
| Aluminium 6063 | 2 700 | Aluminum Association, Teal Sheets December 2025, designation 6063: calculated nominal density. |
| Stainless steel 304 / EN 1.4301 | 7 900 | Outokumpu Core, table 7: Core 304/4301, . |
| Stainless steel 316L / EN 1.4404 | 8 000 | Outokumpu Supra, table 7: Supra , . |
Sources by row: steel, bauforumstahl declaration EPD-BFS-20230271-IBG1-EN distributed by ArcelorMittal, §2.3; aluminium 6060 and 6063, Aluminum Association Teal Sheets, December 2025, calculated nominal densities; stainless steel 304, Outokumpu Core, table 7; stainless steel 316L, Outokumpu Supra, table 7. The measurement temperature specific to the densities is not stated in these tables; “close to 20 °C” indicates the condition in which this calculation is used. Steel catalogue masses are used as published and are not recalculated with these values. Conversion: . bauforumstahl / ArcelorMittal — structural steel sections and bars: nominal density 7 850 kg/m³ ; The Aluminum Association — Teal Sheets, December 2025: nominal density of alloys 6060 and 6063, p. 23 ; Outokumpu Core — physical properties of stainless steel 304 / 1.4301, table 8 ; Outokumpu Supra — physical properties of stainless steel 316L / 1.4404.
Worked examples
Example 1: Estimate the mass of a six-metre IPE 200
Choose IPE 200 from the steel catalogue and a length . The published mass per unit length is ; it is used without recalculating it from rounded dimensions.
The calculation gives a total mass . With , the self-weight is and the total weight .
To estimate the mass to be transported, use m. To include self-weight in a horizontal beam model, use q before any design factors.
Example 2: Prepare a HEA 100 cut
The HEA 100 section, designated HE 100 A in the source, has a mass per unit length of . For a cut length of , the mass is and the total weight is with .
The weight per unit length remains . Shortening the piece reduces its mass and total weight without changing the quantities per unit length.
Example 3: Calculate the mass of a hot-finished circular tube
Select the hot-finished CHS 42,4 × 3,2 tube, with tabulated mass per unit length , then enter . The result is and for .
The self-weight load is . The reference specifies the manufacturing process: a hot-finished product must not be silently replaced with a cold-formed tube of a similar designation.
Example 4: Calculate the theoretical mass of a 6063 aluminium extrusion
The drawing of a 6063 aluminium extrusion gives a material cross-sectional area of . Use and a length of . Internal cavities are already excluded from this area.
The calculated mass per unit length is and the piece's mass is . With , the results are and .
This estimate covers the extrusion alone; assembly fasteners and accessories are added separately.
Example 5: Assess a steel flat bar
A solid rectangular flat bar 100 mm wide and 10 mm thick has a material cross-sectional area of . Enter this area, and .
The mass per unit length is and the total mass is . For , the weight per unit length is and the total weight is .
Conversion from to is essential: area conversion uses the square of the length conversion factor.
Example 6: Compare a 316L stainless steel section
A stainless steel piece has a material cross-sectional area of and a length of . The selected material density is .
The results are , then . At , and .
In this mode, the grade contributes through its density. The result gives no information about the piece's strength, corrosion resistance or stiffness.
Example 7: Use a supplier datasheet in
A datasheet specifies and the cut length is . Select Known mass per unit length mode; no density is required.
The total mass is . With , the self-weight is and the total weight is .
lb denotes mass and lbf denotes force. Their similar numerical values near standard gravity do not make the units interchangeable.
Assumptions and limitations
Section and material: the section is assumed homogeneous and constant along the length considered. For a varying cross-section, divide the piece into sufficiently representative segments and add their masses. For multiple materials, calculate each contribution separately.
Material area: a cutout, groove or cavity must be subtracted from the cross-section. A coating, tube filling, plates, welds or bolts are included only if the mass data explicitly includes them.
Nominal values: tabulated masses and densities remain reference values. Manufacturing tolerances, actual length, cuts and the product's condition may cause the measured mass to vary. The result does not replace a certified or measured mass when one is required.
Self-weight: g is uniform and weight acts vertically. Weight per unit length refers to the actual section length, without horizontal projection, partial factor, dynamic amplification or imposed load. For an inclined beam, loads must be resolved in the model's coordinate system.
Input range: quantities must be finite and nonnegative. For a real piece, area, density, mass per unit length and length are strictly positive. Zero values are still allowed as limiting cases: zero length gives zero mass and total weight; zero g eliminates weight without eliminating mass.
Common mistakes
Confusing with : mass per unit length becomes weight per unit length after multiplication by g. Converting to then requires division by 1 000.
Confusing area with external dimensions: for a tube, width × height includes empty space. Use the cross-sectional area of material, not the area of the enclosing rectangle.
Converting as if they were mm: equals , and equals . Check the area unit selector before comparing two results.
Changing material while remaining in the steel catalogue: the catalogue mass remains that of the selected steel section. For a section made from another material, use Area and material with its actual area.
Multiplying by length twice: μ is already per unit length; one multiplication by L gives total mass. Conversely, a total mass in kg must not be entered in a field.
Adding self-weight twice: if the structural software already calculates it from the material and cross-section, do not add a second load q for the same section.
Frequently asked questions
How do you calculate a section's weight from ?
Multiply mass per unit length by length to obtain mass: . Then multiply by gravitational acceleration to obtain weight: . If you need a result in kilograms for a quotation or transport estimate, use the total mass m.
Does “weight per metre” on a datasheet mean or ?
The commercial term “weight per metre” often means mass per unit length in . In mechanics, weight per metre is a force per unit length in . The datasheet unit distinguishes the two: this calculator displays them separately and reserves the symbol q for weight per unit length.
How do you obtain a tube's cross-sectional area?
Use the material area published by the manufacturer, or calculate the outer area minus the void area. For an ideal circular tube with outer diameter D and inner diameter d, . Both diameters must use the same unit, with the inner diameter smaller than the outer diameter. For a real rectangular tube, corner radii may change the area compared with a sharp-corner estimate.
Why does the catalogue mass differ from ?
Mass per unit length and area are generally published with different rounding. A simplified reconstruction may also omit fillets, corner radii or flange slope. Steel catalogue mode uses the published mass per unit length directly; Area and material mode calculates with the data you enter.
Can a hot-finished tube and a cold-formed tube be interchanged?
Select the reference matching the actual product. The two manufacturing processes remain separate in the catalogue, even when nominal dimensions are similar. This calculation concerns mass and weight; it does not establish equivalence of mechanical properties.
Does the result exactly match the delivered mass?
This is an estimate based on nominal data or the entered mass per unit length. Tolerances, the actual delivered length, coatings and machining operations may alter the actual mass. Use weighing or contractual supplier data if a certified mass is required.