Pressure pipe wall pre-sizing

Invert the same mean-diameter model used by the stress calculator, add an allowance, then check wall thinness.

Created v1.0

By Thibaut Grzelak, Mechanical Analysis Engineer

Piping and pressure
01Calculation inputs
Simplified factor between 1% and 100%; it does not replace the applicable code definition.
Corrosion, erosion or machining; negative manufacturing tolerance is not included.

Results are up to date.

03

Results

Metric
Thickness with allowance c
3.3738mm

Sum tp + c, without rounding to a commercial series.

Resulting inside diameter
107.55mm

Di = Do − 2tn.

Dm/tp ratio
60—

Geometric consistency check using theoretical thickness.

View calculation detailsFormulas, SI conversion, numerical substitution and resultsOpen ↓

Calculation note

Full calculation details

Adopted range: ri/t > 10, with ri = Do/2 − t (inner radius). This limit is a conservative choice for the membrane model, not a code-compliance check. For a calculated thickness, both the theoretical thickness and the thickness including allowance are checked. Thin-membrane pre-sizing for a straight pipe under internal pressure only. The relation inverts σθ = p(Do−t)/(2t), using S·E as a simplified limit. Allowable stress and joint efficiency are already selected by the user. No negative tolerance, temperature effect, external load or code combination is added automatically. Final sizing must be checked using the applicable code and an actually available thickness.

01Formulas and symbols

Formulas used

tptp = p·Do/(2·S·E + p)Exact inversion of the mean-diameter model
tntn = tp + cThickness after adding allowance
DiDi = Do − 2tnGeometric inside diameter
02Assumptions and limits

Scope of validity

  • Thin-membrane pre-sizing for a straight pipe under internal pressure only.
  • The relation inverts σθ = p(Do−t)/(2t), using S·E as a simplified limit.
  • Allowable stress and joint efficiency are already selected by the user.
  • No negative tolerance, temperature effect, external load or code combination is added automatically.
  • Final sizing must be checked using the applicable code and an actually available thickness.
03Validation example

Reference numerical case

  1. p = 40 bar, Do = 114.3 mm, S = 120 MPa, E = 100% and c = 1.5 mm.
  2. tp = 1.87377 mm.
  3. tn = 3.37377 mm.
  4. Di = 107.55246 mm and Dm/tp = 60.
04Direct references