M6 to M24 bolts: tensile stress area and proof loads
Find tabulated values for metric coarse threads in steel property classes 8.8, 10.9 and 12.9. Use them to establish a proof load or interpret a preload calculation — not to select tightening torque directly.
Data from the Optimas table reproducing EN ISO 898-1 · Values reviewed: 15 November 2026 · Full source: Optimas, ISO Metric Thread Proof Loads
Reference table
| Thread × pitch (mm) | As (mm²) | Property class 8.8 (N) | Property class 10.9 (N) | Property class 12.9 (N) |
|---|---|---|---|---|
| M6 × 1.00 | 20.1 | 11 600 | 16 700 | 19 500 |
| M8 × 1.25 | 36.6 | 21 200 | 30 400 | 35 500 |
| M10 × 1.50 | 58.0 | 33 700 | 48 100 | 56 300 |
| M12 × 1.75 | 84.3 | 48 900 | 70 000 | 81 800 |
| M14 × 2.00 | 115 | 66 700 | 95 500 | 112 000 |
| M16 × 2.00 | 157 | 91 000 | 130 000 | 152 000 |
| M18 × 2.50 | 192 | 115 000 | 159 000 | 186 000 |
| M20 × 2.50 | 245 | 147 000 | 203 000 | 238 000 |
| M22 × 2.50 | 303 | 182 000 | 252 000 | 294 000 |
| M24 × 3.00 | 353 | 212 000 | 293 000 | 342 000 |
10 sizes displayed. On mobile, swipe the table horizontally.
How do you read this table?
Example: M12 × 1.75, property class 10.9. The M12 row gives a nominal tensile stress area of 84.3 mm² and a tabulated proof load of 70 000 N, or 70.0 kN. The simplified calculation 84.3 × 830 = 69 969 N explains the order of magnitude; the tabulated value is rounded.
Proof load is neither the bolt's breaking load nor a prescribed minimum preload. A tightening limit must also account for friction, torsion and assembly conditions.
The most common reading errors
- Using πd²/4 for the thread: the nominal cross-section of a 12 mm cylinder is not the tensile stress area of the threaded portion.
- Confusing property classes 8.8 and 10.9: changing property class alone does not qualify a new torque; reassess the joint.
- Confusing coarse and fine threads: M12 × 1.25 does not use the M12 × 1.75 row. For fine threads, consult the “Fine Pitch Thread” table in the Optimas source.
- Reading 70 kN as guaranteed clamping force: actual preload varies with the tool, friction and tightening method.
From table to calculation: recommended workflow
First select the thread and property class, then the applicable proof load. In the preload calculator, define a preload target with the model assumptions. The torque calculator then converts target preload to torque using a justified K. Finally, check nominal bolt stress if the total force it carries is known.
Read the guide: minimum preload and solution selection — a comparison showing why the same wrench is not always enough to meet a preload target.
Preload calculator · Torque calculator · Bolt tensile stress
Source, applicability and verification
These figures are factual values extracted from a technical table published by Optimas, itself presented as compliant with EN ISO 898-1. This page does not claim to reproduce the standard's official text. The values apply to metric coarse threads and the stated steel property classes. Specific conditions may change the applicable values: hot-dip galvanizing (tolerance 6az) and structural bolting are mentioned in the Optimas table notes. Check the actual product's characteristics.
Why tables are useful: they avoid asking readers again for basic data already documented; each linked tool can cite the same source without duplicating its full table.