Skip to content
Formulaxis

Bearings, shafts and joints

Bolt preload: calculation from proof load

Determine a target preload as a chosen fraction of a bolt’s nominal proof load. Enter the tensile stress area of the thread and a documented proof stress. The fraction is a design assumption requiring justification; the calculator selects neither this fraction nor a tightening procedure suited to the joint.

Created on , Revised on v2.0

Method and validation

Bolt preload: calculation from proof load

Initial example : 58 mm².

Initial example : 600 MPa.

dimensionless

Enter a fraction: 0,7 represents 70 %. The fraction must be chosen for the joint.

Initial values are examples.

Results

Nominal proof load Fₚ
34.8kN
Target preload Fi
24.36kN

Substitution in SI units

Fp=(5.8×10-5 m2)×(6×108 Pa)=34.8 kN

Supplied tensile stress area and proof stress, without a strength-class database.

Bolt preload and clamping force

Bolt preload: calculation from proof load · Direct calculationSchematic bolted joint and nut end view. Illustrative thread, with no prescribed ISO geometry. Axial arrows represent tension on a bounded visual scale and disappear at zero force. Calculated quantities: Nominal proof load ; Target preload. Proof load is a reference, not an additional force. Aₛ determines neither nominal diameter nor thread pitch.Fᵢ = 24.36 kNAₛ = 58 mm²Sₚ = 600 MPaNutend viewFₚ = 34.8 kN

Schematic bolted joint and nut end view. Illustrative thread, with no prescribed ISO geometry. Axial arrows represent tension on a bounded visual scale and disappear at zero force. Calculated quantities: Nominal proof load ; Target preload. Proof load is a reference, not an additional force. Aₛ determines neither nominal diameter nor thread pitch.

Illustrative diagram, not to scale.

Estimated reading time : 4 min · 628 words

Calculation details

The steps below use the inputs and units selected in the calculator.

01 · Nominal proof load

FORMULA

Fp=As×Sp

NUMERICAL SUBSTITUTION

Fp=(58 mm2)×(600 MPa)

RESULT

Fp=34.8 kN

02 · Target preload

FORMULA

Fi=u×As×Sp

NUMERICAL SUBSTITUTION

Fi=0.7×(58 mm2)×(600 MPa)

RESULT

Fi=24.36 kN

Proof load and target preload

Preload is the bolt's initial tensile force during tightening, balanced by compression of the parts in contact.

Formulas and symbols

Use the thread tensile stress area Aₛ and a proof stress Sₚ documented for the fastener. Enter u between 0 and 1: 0,7 means 70 %, with no value recommended automatically.

Fp=As×SpProduct of the supplied tensile stress area and proof stress; this load is not a breaking load.

Fi=u×As×SpFraction u of the nominal proof load. The choice of u remains a joint design assumption.

  • Aₛ: thread tensile stress area, default displayed unit: mm2.
  • Sₚ: supplied proof stress, default displayed unit: MPa.
  • u: fraction of proof load, dimensionless.
  • Fₚ: nominal proof load, default displayed unit: kN.
  • Fᵢ: target preload, default displayed unit: kN.

Guidance for interpreting results

Quantity or conditionInterpretation
Tensile stress areaUse thread Aₛ, not the nominal external area
Proof stressDocumented value for the fastener
Fraction 0,7Numerical example representing 70 %
Zero fraction: numerical limitFi=0
Fraction one: numerical limitFi=Fp

NASA — Fastener Design Manual, RP-1228 ; NIST — Guide to the SI, Appendix B.9.

Worked examples

Example 1: Area of 58 mm2, 600 MPa and fraction 0,7

The nominal proof load is 34,8 kN; the target preload is 24,36 kN.

Example 2: Fraction of 0,5 for the same data

The target is half of 34,8 kN, or 17,4 kN.

Example 3: Exercise fraction of one quarter

Assumed u=0.25: Fp=58×600=34.8 kN; Fi=0.25×34.8=8.7 kN.

Example 4: Property class 10.9 M10 × 1,5 bolt: preload example at 70 %

For an M10 with a 1,5 mm pitch, the FDG catalog gives a tensile stress area of 58 mm2 and a proof stress of 830 MPa for property class 10.9. Their product gives a nominal proof load of 48,14 kN. The fraction of 70 % is chosen for this example: it leads to a preload of 33,70 kN, without constituting a tightening instruction for an actual joint.

Fépreuve=58 mm2×830 MPa=48,14 kN ; preload=0,7×48,14 kN=33,70 kN.

Assumptions and limitations

Supplied tensile stress area and proof stress, without a strength-class database. The fraction is an assumption chosen by the user, not a requirement. The joint, relaxation, fatigue and external load distribution are not modeled.

Common mistakes

Confusing preload with external force; using the gross area of the nominal diameter; entering 70 instead of 0,70.

Frequently asked questions

Is the default fraction recommended?

No. It only illustrates the calculation. The fraction depends on the joint, tightening, load and applicable requirements.

Is preload equal to the external load?

No. It is the initial force after tightening. The external load is then distributed between the clamped parts and the bolt according to their stiffnesses.

Is a fraction of one a recommendation?

No. It is only the numerical limit where target equals nominal proof load. Input acceptance does not validate a real tightening specification.

Does target preload remain constant after assembly?

Not necessarily. Settlement, relaxation and thermal changes may alter it. This calculation sets an initial target and does not predict retained service preload.