Bolt preload: calculation from proof load
Determine a target preload as a chosen fraction of a bolt’s nominal proof load. Enter the tensile stress area of the thread and a documented proof stress. The fraction is a design assumption requiring justification; the calculator selects neither this fraction nor a tightening procedure suited to the joint.
Bolt preload: calculation from proof load
Initial example : 58 mm².
Initial example : 600 MPa.
Enter a fraction: 0,7 represents 70 %. The fraction must be chosen for the joint.
Initial values are examples.
Results
Substitution in SI units
Supplied tensile stress area and proof stress, without a strength-class database.
Bolt preload and clamping force
Estimated reading time : 4 min · 628 words
Calculation details
The steps below use the inputs and units selected in the calculator.
02 · Target preload
Proof load and target preload
Preload is the bolt's initial tensile force during tightening, balanced by compression of the parts in contact.
Formulas and symbols
Use the thread tensile stress area Aₛ and a proof stress Sₚ documented for the fastener. Enter u between 0 and 1: 0,7 means 70 %, with no value recommended automatically.
Product of the supplied tensile stress area and proof stress; this load is not a breaking load.
Fraction u of the nominal proof load. The choice of u remains a joint design assumption.
- Aₛ: thread tensile stress area, default displayed unit: .
- Sₚ: supplied proof stress, default displayed unit: MPa.
- u: fraction of proof load, dimensionless.
- Fₚ: nominal proof load, default displayed unit: kN.
- Fᵢ: target preload, default displayed unit: kN.
Guidance for interpreting results
| Quantity or condition | Interpretation |
|---|---|
| Tensile stress area | Use thread Aₛ, not the nominal external area |
| Proof stress | Documented value for the fastener |
| Fraction 0,7 | Numerical example representing 70 % |
| Zero fraction: numerical limit | |
| Fraction one: numerical limit |
NASA — Fastener Design Manual, RP-1228 ; NIST — Guide to the SI, Appendix B.9.
Worked examples
Example 1: Area of , 600 MPa and fraction 0,7
The nominal proof load is 34,8 kN; the target preload is 24,36 kN.
Example 2: Fraction of 0,5 for the same data
The target is half of 34,8 kN, or 17,4 kN.
Example 3: Exercise fraction of one quarter
Assumed : ; .
Example 4: Property class 10.9 M10 × 1,5 bolt: preload example at 70 %
For an M10 with a 1,5 mm pitch, the FDG catalog gives a tensile stress area of and a proof stress of 830 MPa for property class 10.9. Their product gives a nominal proof load of 48,14 kN. The fraction of 70 % is chosen for this example: it leads to a preload of 33,70 kN, without constituting a tightening instruction for an actual joint.
; .
Assumptions and limitations
Supplied tensile stress area and proof stress, without a strength-class database. The fraction is an assumption chosen by the user, not a requirement. The joint, relaxation, fatigue and external load distribution are not modeled.
Common mistakes
Confusing preload with external force; using the gross area of the nominal diameter; entering 70 instead of 0,70.
Frequently asked questions
Is the default fraction recommended?
No. It only illustrates the calculation. The fraction depends on the joint, tightening, load and applicable requirements.
Is preload equal to the external load?
No. It is the initial force after tightening. The external load is then distributed between the clamped parts and the bolt according to their stiffnesses.
Is a fraction of one a recommendation?
No. It is only the numerical limit where target equals nominal proof load. Input acceptance does not validate a real tightening specification.
Does target preload remain constant after assembly?
Not necessarily. Settlement, relaxation and thermal changes may alter it. This calculation sets an initial target and does not predict retained service preload.