Pre-size a cylinder without overlooking the rod and mounting

A cylinder with sufficient pushing force may still be unsuitable because its rod buckles or its stroke is too slow.

Formulaxis · Documented technical demonstration · Revision: 15 November 2026

Short answer. A cylinder must meet at least four groups of criteria: useful force, speed, cycle time and rod stability. Piston diameter alone is insufficient; rod diameter, pressure in each chamber, mounting and stroke strongly affect whether the choice is valid.

We use the historical documentation Bosch Rexroth CDL1, RE 17325/07.09 as a traceable reference case. It lists, among other sizes, a 63 mm piston and 36 mm rod with their effective areas. These data let us check geometry, then study fictional operation at 100 bar and 20 L/min. A historical catalogue does not establish current commercial availability.

1. Read the manufacturer's documentation first

Working pressure →Piston Ø 63 mm · rod Ø 36 mm · stroke 400 mm
Original diagram: pressure, piston, rod and stroke. Back pressure in the opposite chamber is not shown.
Reference CDL1Piston / rodCap-end areaAnnular areaIdeal extension force at 160 bar
CDL1 series50 / 28 mm19.63 cm²13.47 cm²31.40 kN
CDL1 example63 / 36 mm31.16 cm²20.98 cm²49.85 kN
CDL1 series80 / 45 mm50.24 cm²34.34 cm²80.38 kN

Selection from “Area, force, flow”, p. 3, Bosch Rexroth RE 17325/07.09. Manufacturer forces are theoretical; this table shows the stated 160 bar case.

Find these data with the conversion bar × cm² → N.

2. Five checks before selection

1 Determine useful force, not just pump pressure

The product pA gives theoretical cylinder force. For extension, A = πD²/4; for retraction, A = π(D² − d²)/4. Here we assume 100 bar available at the cylinder and a simplified coefficient η = 0.90, not supplied by Rexroth. For real design, calculate the chamber pressure difference and assembly friction.

F_extension = p × A_piston × η ; F_retraction = p × A_annular × η
100 bar, simplified η 0.90Extension28.06 kNRetraction18.89 kN
Forces in both chambers · original Formulaxis diagram, values for this example only

2 Derive speed from actually available flow

At constant flow, extension speed is Q/A_piston; retraction is faster because annular area is smaller. In a real installation, the 20 L/min flow may be shared or limited by the pump, directional valves, controllers and losses.

v_extension = Q / A_piston ; v_retraction = Q / A_annular
20 L/min · same flowExtension106.9 mm/sRetraction158.8 mm/s
Flow and speed · original Formulaxis diagram, values for this example only

3 Convert stroke into time and volume

For a 400 mm stroke, cap-end volume is about 1.247 L; at 20 L/min this takes 3.74 s theoretically. Actual cycle time may include end cushioning, acceleration and switching delays.

t_extension = A_piston × stroke / Q ; t_retraction = A_annular × stroke / Q
400 mm stroke · same 20 L/minExtension3.74 sRetraction2.52 s
Stroke time · original Formulaxis diagram, values for this example only

4 Check buckling with mounting conditions

A slender compressed rod can buckle despite apparently adequate pushing force. Bosch Rexroth's document distinguishes Euler calculation in the slender range from a Tetmajer-type relationship outside it, with a safety factor of 3.5 in this documentation. Buckling length is not automatically cylinder stroke: it depends on mounting points and guidance.

F_Euler = π² E I / L_k² ; I_rod = πd⁴/64 ; illustrative F_allow = F_Euler/3.5
Euler / 3.5 versus effective LkLk = 1 m48.82 kNLk = 2 m12.21 kNExercise limit: 25 kN
Mounting influence · original Formulaxis diagram, values for this example only

5 Check requirements not included in the model

Under side load, a cylinder is not an ideally guided beam; inspect mountings, bushings, joints, eccentricity, pressure peaks and shocks. Maximum catalogue pressure replaces neither available operating pressure nor strength checks on mounting components.

The product p × A alone cannot validate the designPressureAt the chambersStabilitySupports and rodCycleEnd of stroke
Additional checks · original Formulaxis diagram, values for this example only

3. Numerical example: Ø63/36, 100 bar, 400 mm stroke

Rexroth publishes Ø63/36 geometry and 31.16 cm² cap-end area. Using p = 100 bar, η = 0.9 and Q = 20 L/min as scenario assumptions, we obtain the following results.

QuantityIndependent resultComment
Extension force28.06 kN100 bar × 31.17 cm² × 0.9
Retraction force18.89 kNSmaller annular area
Extension / retraction time3.74 s / 2.52 sFull flow available at the cylinder
Euler, Lk = 1 mFcrit ≈ 170.9 kNFcrit/3.5 ≈ 48.8 kN (check assumption)
Euler, Lk = 2 mFcrit ≈ 42.7 kNFcrit/3.5 ≈ only 12.2 kN

E = 210 GPa assumed for the steel rod; Lk is an effective buckling length imposed to illustrate mounting influence, not a length derived from the 400 mm stroke.

Technical decision: If the required compressive force were 25 kN, force balance alone (28.06 kN extension) would be favorable in this scenario. But the rod may experience theoretical pA thrust of about 31.2 kN when blocked, even though estimated useful thrust is reduced by η. Compare buckling with maximum plausible force, not just the required 25 kN. At Lk = 2 m, Euler divided by 3.5 falls to about 12.2 kN: the buckling check becomes unfavorable. Reconsider the mounting/guidance or rod.

Explore the same manufacturer example

Fixed Ø63/36 geometry (Rexroth); effective pressure, flow and buckling length are editable assumptions.

28.06 kNExtension force with η = 0.90
3.74 sTheoretical extension time, 400 mm stroke
48.82 kNEuler / 3.5 for selected Lk

4. Design tips to remember

Stroke is not buckling length

The critical quantity is the distance between effective lateral restraints in the most unfavorable loaded position. End-pinned mounting or large rod extension may impose an unfavorable Lk. Rexroth distinguishes mounting types and free-length factors in its diagrams; do not arbitrarily select “pinned–pinned”.

Retraction force may govern

With a single rod, annular area may be much smaller than full piston area. If the machine must pull a load rather than push it, sizing solely by extension force may produce an undersized cylinder.

Do not confuse catalogue pressure with available pressure

Rexroth uses 160 bar nominal pressure for its tables; our illustrative machine operates at 100 bar at the cylinder. Using the 160 bar table force as actually available force would introduce a 60 % error in pA even before losses.

Euler calculation requires a slender rod and essentially axial compression. A short rod, eccentric load, combined bending or different material grade may require another model and different criteria.

5. Links to Formulaxis calculators

Related reference: area / force table for a Rexroth cylinder series. Range data and buckling method must be updated using the manufacturer documentation selected for the project.

Sources and data status

Numerical values are retained in this document even if URLs change. The tables are reconstructed selections with source attribution, not full copies of brochures. Formulaxis calculations and teaching assumptions are identified separately.

  1. Bosch Rexroth — CDL1, technical data sheet RE 17325/07.09Table p. 3: piston/rod and areas; p. 19: buckling criteria; historical catalogue, confirm before ordering today.

Sources consulted / results cross-checked on 15 November 2026. Data sheets and catalogues may be revised: check the current edition for a real project.