Bearing: calculating the static safety factor
Calculate a bearing's static safety factor s₀ from its basic static load rating C₀ and the previously determined equivalent static load P₀. Then compare the ratio with the criterion appropriate for the application.
Bearing: calculating the static safety factor C₀/P₀
Initial example : 20,000 N.
Initial example : 5,000 N.
Initial values are examples.
Results
P₀ must come from the manufacturer's formula specific to the bearing; coefficients and any maxima are not derived.
Applied formulas
Values are substituted in SI units and results are shown in the selected units.
Estimated reading time : 3 min · 576 words
Calculation details
The steps below use the inputs and units selected in the calculator.
Interpreting the static safety factor
The static safety factor compares the bearing's basic static load rating with its equivalent static load. This page calculates the ratio from C₀ and P₀ already determined for the selected bearing. It does not automatically construct P₀ from radial and axial forces.
Formulas and symbols
Enter C₀ from the catalogue and P₀ established using the bearing-specific static relation. Both are forces; do not replace P₀ with the equivalent dynamic load P.
Dimensionless ratio. Its value must be compared with a justified requirement for the bearing and its operating conditions.
- C₀: basic static load rating, default displayed unit: N.
- P₀: previously determined equivalent static load, default displayed unit: N.
- s₀: dimensionless static safety factor.
Guidance for interpreting results
| Quantity or condition | Interpretation |
|---|---|
| C₀ | Basic static load rating from the catalogue |
| P₀ | Equivalent load calculated for the bearing family |
| s₀ | Dimensionless ratio to compare with the applicable criterion |
| Double load, fixed capacity | Factor halves |
| Capacity and load in the same unit | Units cancel in the ratio |
SKF — Cooper split roller bearings and bearing units ; NIST — Guide to the SI, Appendix B.9.
Worked examples
Example 1: Static load rating 20 kN, equivalent load 5 kN
The static ratio is 4.
Example 2: Same load rating under a load of 10 kN
The static ratio is 2.
Example 3: Forces in different units
; : after conversion.
Example 4: Bearing under high static load: ,
The static factor compares static load rating with equivalent load. Here it is 1,6. It must be compared with the criterion required by the application (slow rotation, noise, precision, shocks): a value close to 1 leaves little margin.
.
Assumptions and limitations
P₀ must come from the manufacturer's formula specific to the bearing; coefficients and any maxima are not derived. No universal minimum value of s₀ is prescribed: it depends in particular on shocks, accuracy and operation.
Common mistakes
Using the dynamic load rating changes the criterion being compared: obtain the static rating.
Reusing the dynamic load may ignore static factors: determine each load separately.
Mixing newtons and kilonewtons without conversion changes the ratio by a factor of a thousand: check units.
Using an average load hides a peak: check the relevant static case.
Concluding that a ratio above one is sufficient overlooks the application: compare with the referenced criterion.
Frequently asked questions
Does a result greater than 1 guarantee the bearing?
No. The appropriate minimum factor depends on the application and the manufacturer's recommendations.
Can I replace P₀ with the dynamic load P?
No. The two equivalent loads correspond to different criteria and their coefficients may differ.
Which cycle load should be checked?
Check relevant static peaks and shocks according to the maker’s method. A cycle average can hide the limiting case; the calculator does not identify it.
Does the factor depend on force units?
No, after consistent conversion. Mixing raw numbers in N and kN without conversion gives an incorrect ratio.